Real Life Incident: Complicated Procedure Leads To Total Failure Of Fast Rescue Craft (FRC)

A ferry was on a scheduled run between two ports. The crew planned to carry out a routine test of the stored power launching system with the Fast Rescue Craft (FRC) during the transit. A toolbox talk was conducted before the test, and the procedure for the stored power launch was discussed. The vessel was stopped for the drill to take place.

The vessel-specific procedure for the stored power launch of the FRC consisted of 20 steps, including the operation of seven different ball valves in the davit’s hydraulic system, located on two decks. The crew worked under the instruction of a senior officer. When all the valves were thought to be in the correct positions and the boat was slewed out into the launching position, the order was given to operate the launch cable. When the launch cable was pulled, the FRC immediately fell about 9m to the water. Thankfully, the FRC was uncrewed, so no injuries were incurred. However, the FRC was damaged beyond repair and had to be replaced.

Ferry
Image for representation purpose only

The FRC was recovered, and the launch system was inspected. It was found that a valve for draining pressure from the hydraulic system was mistakenly left in the open position. The preliminary investigation found, among other things, that ball valve 9 (BV9) had been mistaken for BV6. The operation of BV9 was not included in the procedure for launching the FRC using stored power.

Once BV9 was put in the open position, there was no hydraulic oil pressure available in the system to arrest the fall of the FRC once the launch cable was pulled.

The stored power launch system was subsequently tested using the documented procedure with the correct valve sequence and was proven to work without incident.

Lessons Learned

  • Ideally, a procedure should fit on one page and be as simple as possible.
  • In this case, the two valves were close together, and the identification label for BV6 was sideways, so that it was not clear which valve it referred to 9 and 6 can be confused when the orientation of the sign is not made clear.
  • The BV9 valve was in the foreground and painted yellow, thus attracting more attention than the BV6 valve, which was in the background and more restrained in colour.

Disclaimer :
The information on this website is for general purposes only. While efforts are made to ensure accuracy, we make no warranties of any kind regarding completeness, reliability, or suitability. Any reliance you place on such information is at your own risk. We are not liable for any loss or damage arising from the use of this website.

Disclaimer :
The information on this website is for general purposes only. While efforts are made to ensure accuracy, we make no warranties of any kind regarding completeness, reliability, or suitability. Any reliance you place on such information is at your own risk. We are not liable for any loss or damage arising from the use of this website.

Popular maritime courses

100 SIRE/CDI Inspection Observations for Engineers

Prepare for SIRE/CDI inspections with practical guidance covering 100 key observations every marine engineer should understand and apply.

Ballast Water Management and Treatment System Course

Master ballast water management with practical training for safe, compliant ship operations and confident onboard environmental compliance.

Advanced Draft Survey

Build Draft Survey skills through practical training for accurate cargo calculations, vessel stability, and efficient survey operations.

Subscribe To Our Daily Newsletter

    By subscribing, you agree to our Privacy Policy  you can unsubscribe anytime.

    BE THE FIRST TO COMMENT

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    [the_ad_group id=”451041″]